Changelog 5.3

Updates with following changes:

5.301.13 published 27.04.2016

– Corrected calculation of HGA and HF in earthquake design
– changed «partial safety factor material» for non DIBt listed material from YM = 1,5 to YM ≥ 1,30 (suggested value 1,34 –> may be varied according needs by user)
– corrected printout mismatch and ####

5.301.11 has been published 21.03.2016

updated all calculation routines + formula + values + reports to the latest DVS 2205 edition 12/2015 

– added detailed calculation of agitator / mixer influence mounted to flat roof on cylindrical tanks

– added new sheet thickness 22,5 mm (may be chosen in basic setup)

– added pressure calculator (rectangular tanks) in metric and imperial dimension

– added pressure / vacuum calculator (cylindrical tanks) in metric and imperial dimension

– revised determination of wind-load (within Europe)

– added wind load calculator (cylindrical tanks) for any local windload in metric and imperial dimension

– revised determination of snow-load (within Europe)

– changed and added volume calculation in cylindrical tanks V95; V100; V

– revised + corrected document templates

– added dimensions of vertical beam into calculation result window

new module Z 1.2 Long term pressure in rectangular tanks (add-on against cost)

– in module Z 7 twin wall sheets (sandwich panels) added calculation for tanks with circumferential stiffener (Type 3)

5.210.05 published 15.01.2016

– bug fix, mismatch under WIN 10

5.210.04 published 12/2015

– correced templates in various languages

5.210.03 published 11/215

– correct templates in CZ

5.210.02 published 10.07.2015

– bug fix, mismatch if M5 not activated
– corrected all templates to avoid #######
– corrected manufacturers address on first Report page

5.210.01 published 05.06.2015 (Module 2a.2 only useable against payment)

Module Z 2a.2 / Part 1
– sloped base, with parallel support (acc. DVS 2205)
– M2a bug fix in dimension calculation button (data transfer)

5.200.21 published 16.04.2015

– M2a fix bug of tagged «earthquake» for non M5 user

5.200.20 published 09.04.2015

– M5 corrected value transfer to report (γi)
– M2a corrected value transfer to report (bö + sö)
– M1 corrected report template for horizontal steel stiffener (WR+ IR –> WH + IH)
– M2a corrected report template for base + lifting lug generally (in DE / EN / FR)

5.200.19 published 11.03.2015

– M2a move «retention tank» button
– M2a repair bug when creating a retention tank